µCT Imaging Facility at Stemmler Hall

2 18

µCT Scanners

2 520

There are 4 µCT systems at Stemmler Hall: the Scanco Medical µCT 35µCT 45 and the Scanco Medical vivaCT 40vivaCT 80. All these µCT systems are used to examine diverse materials from bone samples to medical implants. Currently, the µCT 35 and µCT 45 are used to study the trabecular bone structure of tibiae, femora, and vertebrae harvested from rats and mice, whereas the vivaCT 40 and vivaCT 80 are used to scan rats in vivo under anesthesia, rat and mouse humeri, pellets, and medical devices.

2 9 a 8 30 39 39 3b 9 b a 8 22 2c 2c 2a 9 8 2b 1c 20 1c 9 8 2c 24 1c 1c 9 8 2e 1e 1c 1c 9 8 34 1e 1e 22 9 8 27 20 20 20 9 b a
ModelScanco µCT 35Scanco µCT 45Scanco vivaCT 80
Useex vivo specimenex vivo specimenin vivo animal
X-ray Energy45, 55, 70 kVP45, 55, 70, 90 kVP45, 55, 70 kVP
Max Scan SizeØ37.9mm x 120mm Ø50mm x 120mmØ80mm x 145mm
Max Sample SizeØ75.8mm x 140mmØ90mm x 120mmØ90mm x 500mm
Best Image Voxel Size3.5µm (Ø: 7mm)3.0µm (Ø: 9mm)10.4µm (Ø: 31.9mm)
Location335A Stemmler Hall335A Stemmler Hall368B Stemmler Hall
2 1e

Anesthesia Machines

2 a4

This facility is equipped with two rodent anesthesia machines (Supera Anesthesia, Clackamas, OR) for in vivo µCT imaging studies. 

2 22

µCT Analysis Computers

2 e4

The "microCT Analysis (I)" and " microCT Analysis (II)" are located in 315 Stemmler Hall, designated for µCT imaging analysis on Scanco software.

2 e5

The "Dragonfly Workstation" is located in 324 Stemmler Hall, designated for µCT imaging analysis on Dragonfly software.

2 115

All of them can be accessed either onsite or remotely. The use of these computers requires making reservations in advance via Google calendar. For calendar access, send a request to pcmd.microct@gmail.com

2 35

µCT Imaging Facility at the CMC VAMC/TMRC

2 176

There are 2 µCT systems located at the Translational Musculoskeletal Research Center (TMRC) of the CMC VAMC: the Scanco Medical µCT 50 and the Scanco Medical vivaCT 75.

2 9 a 8 30 3e 40 9 8 22 2c 2a 9 8 2b 20 1c 9 8 2c 22 1e 9 8 2e 1d 1c 9 8 34 14 13 9 8 27 12 12 9 b a
ModelScanco µCT 50Scanco vivaCT 75
Useex vivo specimenin vivo animal
X-ray Energy45, 55, 70, 90 kVP45, 55, 70 kVP
Max Scan SizeØ50mm x 120mm Ø79.9mm x 145mm
Max Sample SizeØ100mm x 160mmØ80mm x 500mm
Best Image Voxel Size0.5µm10µm
LocationTMRCTMRC
2 4c

High Resolution Peripheral QCT (HR-pQCT) Imaging Facility at CTRC

2 152

The HR-pQCT (Scanco XtremeCT II) is located at the Clinical and Translational Research Center (CTRC), for in vivo imaging bone microarchitecture of patients’ distal radius and tibia with a voxel size down to 60 μm.